Fire-Rated Door Assemblies
Fire-Rated Doors in Buffalo, NY
UL-labelled fire door assemblies from 20 minutes to 3 hours, supplied, installed and inspected. A fire door is only compliant if the door, frame, glass and hardware all carry matching labels.
Fire door assemblies that actually pass inspection
A fire door is not a product, it is an assembly. The door, the frame, the glazing, the hinges, the closer and the latching hardware all have to be listed and labelled for the rating, and they all have to be installed the way the listing says. A rated door hung in an unrated frame is not a rated opening, and a fire marshal will fail it.
We supply and install rated hollow metal and wood assemblies across Buffalo, and we inspect existing ones. NFPA 80 requires fire door assemblies to be inspected annually, with the results documented, something a lot of Western New York building owners discover only when an inspector asks for the paperwork.
Most failures we find are small and fixable: a closer that no longer latches the door, a missing label, field-drilled holes, painted-over intumescent seals, or a kick plate installed too high. We list what fails, fix what can be fixed, and replace only what genuinely has to be replaced.
Ratings
Fire door ratings and where they are used
The rating required comes from the wall the door sits in, not from preference.
20 Minute
Typically corridor and smoke-barrier doors. Often wood assemblies in office, hotel and multifamily corridors.
45 Minute
Common for one-hour rated partitions and some stairwell and utility openings.
60 & 90 Minute
The most common commercial ratings. Stairwell enclosures, exit passageways, and separations between occupancies.
2 & 3 Hour
Fire walls and major separations, usually in industrial or large mixed-occupancy buildings. Hollow metal only.
Specifications
Fire door assembly requirements
What has to be right for an opening to be compliant in New York State.
The Assembly
Door
UL-labelled steel or mineral-core wood, label permanently affixed and legible
Frame
Labelled frame rated to match or exceed the door
Glazing
Listed fire-rated glass, wire glass or ceramic, within permitted area limits
Label integrity
Labels must not be painted over, removed or made illegible
Required Hardware
Self-closing device
A closer that fully closes and latches the door from any position
Positive latching
The latch must engage the strike. A door that closes but does not latch fails
Hinges
Steel ball-bearing hinges, correct count for door height and weight
Seals
Intumescent and smoke seals where the listing requires them
Inspection & Records
Frequency
Annual inspection of fire door assemblies under NFPA 80
Documentation
Written record of each opening, deficiencies found and corrective action
Common failures
Non-latching doors, field-drilled holes, missing labels, blocked-open doors
Repairs
Must restore the assembly to its listed condition, using listed components
Product Gallery
Fire-rated doors and glazing
Labelled assemblies supplied across Western New York.

UL-labelled assembly
Door, frame, glass and hardware labelled as a set.
Rated double doors
Pairs with coordinators and matching labelled frames.
Rated wire glass lite
Labelled glazing for rated corridors and stairwells.
Rated office doors
Rated separations that still look like office doors.
Rated wood pair
Architectural finish with a compliant core.
Installed rated opening
Inspected, labelled and ready for the fire marshal.Industries We Serve in Buffalo
Buildings that need rated openings
Almost every commercial building in Buffalo has fire doors, and almost all of them need annual inspection.
Multifamily & Property Mgmt
Unit entries, stairwell doors, trash and common areasHotels & Hospitality
Guest room and corridor doors with sound and fire ratingsSchools & Institutional
Rated stairwells, classroom corridors, utility roomsMedical & Dental
Cleanable faces, ADA operators, rated separationsWarehouse & Industrial
Exterior man doors, dock personnel doors, louvered mechanical roomsMunicipal & Government
Spec-compliant assemblies with submittal documentationOffices & Professional
Suite entries, corridors, conference and reception doorsGeneral Contractors
Door packages priced from plans and delivered to schedulePricing Guidance
What do fire-rated doors and inspections cost?
Rated assemblies carry a premium over standard doors because every component must be listed.
Fire door inspection
Annual NFPA 80 inspection with written documentation of each opening and any deficiencies found. Volume pricing for larger buildings.
Rated assembly supplied
Labelled door, matching labelled frame and listed self-closing, latching hardware. Wood 20-minute assemblies sit lower; 3-hour steel sits higher.
Supplied & installed
Complete labelled assembly installed to the listing. Deficiency repairs on existing openings are usually far less.
What moves the price:
the rating required, steel versus wood, rated glazing area, hardware listing requirements, and whether the existing frame is labelled and can be retained.Compliance Guide
Fire door compliance without the surprises
Read the label before you buy anything
Every listed fire door carries a permanent label giving the rating and the listing agency. If you cannot find or read a label, the opening cannot be treated as rated. Painting over a label is one of the most common ways a compliant door quietly becomes a non-compliant one.
Closing is not the same as latching
The single most common inspection failure is a door that swings shut but does not positively latch. In a fire, an unlatched door will be pushed open by pressure. If the latch does not engage the strike every time, from any opening angle, the assembly fails.
Never wedge a fire door open
A blocked-open fire door is a violation and, in a fire, a route for smoke and flame. If a door genuinely needs to stand open for operations, the correct answer is a listed hold-open device tied to the fire alarm, which releases automatically on activation.
Magnetic hold-opens are the compliant option
Electromagnetic hold-opens keep the door open during normal use and drop it on alarm. They are inexpensive next to a violation notice.
Test the release at every fire drill
A hold-open that no longer drops on alarm is a failed assembly. Testing it during scheduled drills costs nothing and catches it early.
Field modifications void the label
Cutting a rated door down, drilling unlisted holes, adding a non-listed lite kit or fitting a kick plate above the permitted height all void the listing. Order the door to the correct size and configuration; do not modify it on site.
Keep the paperwork
NFPA 80 requires the inspection record to be retained and made available. In practice, the building owner who has a written annual record has a far easier conversation with an inspector than one who says the doors were checked but has nothing on paper.
Local Coverage
Fire door supply, installation and inspection across Buffalo, NY
We inspect and service fire door assemblies for property managers, schools, healthcare facilities and municipal buildings throughout Erie and Niagara counties, and can document a whole portfolio opening by opening.
- Buffalo
- Cheektowaga
- Amherst
- Tonawanda
- West Seneca
- Orchard Park
- Hamburg
- Lackawanna
- Niagara Falls
- Lockport
- Depew
- Williamsville
- Clarence
- Grand Island
- Kenmore
- East Aurora
Frequently Asked Questions
Fire-rated doors: frequently asked questions
NFPA 80 requires fire door assemblies to be inspected at least annually, with a written record kept of each opening, any deficiencies found and the corrective action taken.
The door, frame, glazing and hardware must all be listed and labelled for the rating, and installed per the listing. The door must be self-closing and positively latching. Labels must be present and legible.
No. Cutting a rated door beyond the small tolerances allowed by its listing voids the label and the opening is no longer compliant. The door has to be ordered to the correct size.
By far the most common reason is that the door closes but does not positively latch, usually due to a worn closer, a misaligned strike or a dragging door. Missing labels and field-drilled holes are the next most common failures.
Only with a listed hold-open device connected to the fire alarm system, which releases the door automatically on activation. Wedges, hooks and props are violations.
The rating comes from the rating of the wall the opening sits in, which is set by the building code and the occupancy. We check the wall rating as part of the assessment rather than guessing from the old door.
Yes. Every inspection produces a written record per opening covering the components checked, deficiencies found and corrective action, which is what an inspector or insurer will ask to see.